Custom Search
 
  
 
TM 55-1905-242-14
0081 00
INSTALLATION--EMERGENCY ENGINE SHUTDOWN CONTROL
1.
Adjust the cable adjusting nut (10) so that the upper end of the cable (7) will slide through the console far enough to
permit installation of the upper cable nut (8) and washer (9). Install the upper cable nut hand tight on the cable, and
install the T-handle (6).
2.
Secure the upper end of the cable (7) to the console by tightening the cable adjusting nut (10).
3.
Route the new cable (7) through the vessel, securing it in the same places as the old cable.
4.
Push the T-handle (6) all the way down, and then pull it back up approximately 1/4 inch (6 mm).
5.
Install the locknut (14) and swivel fitting (12) onto the lower end of the cable (15) and adjust it so that the swivel end stud
slips easily through the hole in the release arm (13).
6.
Secure the swivel fitting (12) to the release arm (13) with the nut (11).
7.
Test the operation of the system as described in WP 0053 00.
8.
Remove the lockouts and tagouts, start the engine, and test the operation of the cable.
END OF WORK PACKAGE
00810081 00-3
00-3/4 blank


 


Privacy Statement - Copyright Information. - Contact Us