Custom Search
 
  
 
TM 55-1905-242-14
0096 00
REMOVAL
WARNING
Replace or repair components only after the affected circuit has been secured, locked
out, and tagged out. Performing replacement with the circuit energized may result in
damaged equipment and serious injury or death to personnel.
1.
Set to OFF, lock out, and tag out the battery isolation switches in accordance with FM 55-502.
2.
Set the multimeter to the Vdc setting and place its leads on the circuit breaker's terminals (1). If 0 Vdc is noted, proceed
to the next step. If voltage is noted, ensure that the battery isolation switches are properly secured.
3.
Label the wiring connected to the circuit breaker's terminals (1).
4.
Remove the screws (2) and lockwashers (3) that secure the wiring to the circuit breaker's terminals (1).
5.
Remove the nut (4) and flat washer (5) that secure the circuit breaker to the panel (6).
6.
Remove the screws (7) that secure the circuit breaker to the panel (6).
7.
Remove the circuit breaker from the panel (6).
6
5
7
0096 00-2


 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business