Tweet |
Custom Search
|
|
|
||
TM 55-1905-242-14
0096 00
INSTALLATION
1.
Procure a new circuit breaker.
2.
Position the circuit breaker in the panel (6) and secure it with the screws (7), nut (4), and flat washer (5).
3.
Connect the wiring to the circuit breaker's terminals (1) using the labels from step 3 of Removal as a guide and secure it
with the screws (2) and lockwashers (3).
4.
Remove the lockouts and tagouts, set to ON the battery disconnect switches, and check the operation of the circuit.
END OF WORK PACKAGE
00960096 00-3
00-3/4 blank
|
||