Tweet |
Custom Search
|
|
|
||
TM 55-1905-242-14
0097 00
REPLACE--TOGGLE SWITCH (POWER AND TEST) (continued)
8.
If no further repairs will be made, remove the lockouts and tagouts and check the operation of the system.
REPLACE--SELECTOR SWITCH
1.
Loosen the screws (1) that secure the cover clamps (2). Swing the cover clamps clear and remove the ground detector
cover (3).
2.
Set the multimeter to the Vdc (Volts direct current) setting and check for voltage at the terminals on the selector switch
(4). If no voltage is noted, proceed to the next step. If voltage is noted, ensure that the port and starboard battery
isolation switches are set to OFF.
3.
Label and disconnect the wiring (5) from the selector switch (4).
4.
Remove the nut (17) and washer (18) that secure the selector switch (4) to the ground detector cover (3). Remove the
selector switch (4) from the ground detector cover.
5.
Position the new selector switch (4) in the ground detector cover (3) and secure it with the nut (17) and washer (18).
6.
Connect the wiring (5) to the selector switch (4) using the labels from step 3 as a guide.
7.
Position the ground detector cover (3) on the ground detector box (7) and secure it with the cover clamps (2) and screws
(1).
8.
If no further repairs will be made, remove the lockouts and tagouts and check the operation of the system.
END OF WORK PACKAGE
0097 00-4
|
||