Custom Search
 
  
 
TM 55-1905-242-14
UNIT MAINTENANCE
FOR LANDING CRAFT, MECHANIZED (LCM-8) (ALL VESSELS WITH MOD 2 APPLICATION)
BATTERY CHARGER, TEST
INITIAL SETUP:
Tools and Special Tools:
Personnel Required:
Tool Kit, Mechanic's Rail and Marine
Two Watercraft Engineers, 88L
(Item 1, Table 1, WP 0230 00)
Multimeter (Item 2, Table 1, WP 0230 00)
TESTING
1.
Set to ON the battery charger circuit breaker in the 220/110 Volt distribution box.
2.
Set the multimeter to the Vdc (Volts direct current) setting and check the battery voltage on both battery banks. The
voltage should be 27 Vdc to 29 Vdc on both battery banks. If either battery bank shows a lower charging voltage, notify
general support maintenance for repair.
END OF WORK PACKAGE
00980098 00-1
00-1/2 blank


 