Custom Search
 
  
 
TM 55-1905-242-14
UNIT MAINTENANCE
FOR LANDING CRAFT, MECHANIZED (LCM-8) (ALL VESSELS WITH MOD 2 APPLICATION)
RF SEA 1630 COUPLER, REPLACE
INITIAL SETUP:
Tools and Special Tools:
Personnel Required:
Tool Kit, Mechanic's Rail and Marine
Two Watercraft Engineers, 88L
(Item 1, Table 1, WP 0230 00)
Multimeter (Item 2, Table 1, WP 0230 00)
References:
FM 55-502
Equipment Condition:
TM 55-1905-242-24P (WP 0042)
SEA 330 MF/HF RADIO circuit breaker set
to OFF, locked out and tagged out IAW
FM 55-502
REMOVAL
WARNING
Replace or repair components only after the affected circuit has been secured, locked
out, and tagged out. Performing replacement with the circuit energized may result in
damaged equipment and serious injury or death to personnel.
1.
Set the multimeter to the Vdc (Volts direct current) setting and check for voltage at the coupler (2) terminals. If no voltage
is noted, proceed to the next step. If voltage is noted, ensure that the circuit breaker is properly secured.
2.
Label and disconnect the wiring (1) from the coupler (2).
3.
Remove the bolts (3) that secure the coupler (2) to the accommodation module top.
0115 00-1


 