TM 55-1905-242-14
0132 00
REMOVAL (continued)
3.
Label and disconnect the wiring (1) from the pump's microswitch (2).
4.
Disconnect the piping from the intake (3) and outlet (4) ports.
5.
Remove the bolts (5), nuts (6), and washers (7) that secure the pump to its mount.
4
5
2
7
3
6
1
INSTALLATION
1.
Position the pump on its mount and secure it with the bolts (5), nuts (6), and washers (7).
2.
Connect the piping to the intake (3) and outlet (4) ports.
3.
Connect the wiring (1) to the pump's microswitch (2) using the labels from step 3 of Removal as a guide.
4.
Clear the lockouts and tagouts and check the operation of the system, ensuring that the pump delivers water to the
nozzles and that it does not leak.
5.
Install the void cover on Void 6 and terminate the confined space entry permit.
END OF WORK PACKAGE