Tweet |
Custom Search
|
|
|
||
TM 55-1905-242-14
UNIT MAINTENANCE
FOR LANDING CRAFT, MECHANIZED (LCM-8) (ALL VESSELS WITH MOD 2 APPLICATION)
WINDSHIELD WASHER PUMP, REPLACE
INITIAL SETUP:
Tools and Special Tools:
Equipment Condition (continued):
Tool Kit, Mechanic's Rail and Marine
WIPERS STBD & WASH PUMP circuit breaker set to
(Item 1, Table 1, WP 0230 00)
OFF, locked out and tagged out IAW FM 55-502
Multimeter (Item 2, Table 1, WP 0230 00)
Personnel Required:
Equipment Condition:
One Watercraft Engineer, 88L
Void 6 prepared for confined space entry with
One Entry Supervisor/Attendant
Confined Space Entry Permit secured, IAW
(Trained in Confined Entry Space)
Organizational Confined Space Entry SOP and
FM 55-502
References:
FM 55-502
Organizational Confined Space Entry SOP
TM 55-1905-242-24P (WP 0053)
REMOVAL
WARNING
Only properly trained personnel may enter confined spaces, or act as entry supervisors
and/or attendants for those working in confined spaces. Before entering into a confined
space, the space must be cleared for entry and a Confined Space Entry Permit must be
secured. All entry into confined spaces must be in accordance with the Organizational
Confined Space Entry Standard Operating Procedure and FM 55-502. Entry into an
uninspected confined space may result in serious injury or death.
1.
Remove the void cover from Void 6 and prepare it for confined space entry in accordance with the Organizational
Confined Space Entry SOP and FM 55-502.
WARNING
Replace or repair components only after the affected circuit has been secured, locked
out, and tagged out. Performing replacement with the circuit energized may result in
damaged equipment and serious injury or death to personnel.
2.
Set the multimeter to the Vdc (Volts direct current) setting and place one multimeter lead on each of the two power wires
(1) connected to the pump's microswitch (2). If no voltage is noted, proceed to the next step. If voltage is noted, ensure
that the pump's circuit breaker is properly secured.
0132 00-1
|
||