Custom Search
 
  
 
TM 55-1905-242-14
0144 00
INSTALLATION--STRAINER
1.
Position the strainer (5) between the seacock (6) and the piping (7) with its gaskets (8) and secure it with the nuts (4),
lockwashers (3), flat washers (2), and bolts (1).
2.
If no other components will be removed, clear the lockouts and tagouts, OPEN the seacock, and check for leaks.
REMOVAL--PIPING, VALVES, FITTINGS
1.
Remove the bolts (9) and nuts (10) that secure the flange to the pump (11).
2.
Remove the bolts and nuts from the flange at the other end of the piping section (12).
3.
Remove the piping section (12).
INSTALLATION--PIPING, VALVES, FITTINGS
1.
Position the piping section (12) with its gaskets (13) and secure it with the bolts (9) and nuts (10).
2.
Remove the lockouts and tagouts and OPEN the seacock.
3.
Operate the fire monitor (WP 0026 00) and check the work area for leaks.
END OF WORK PACKAGE