Custom Search
 
  
 
TM 55-1905-242-14
UNIT MAINTENANCE
FOR LANDING CRAFT, MECHANIZED (LCM-8) (ALL VESSELS WITH MOD 2 APPLICATION)
FIREFIGHTING AND BALLAST SYSTEM PIPING, VALVES, STRAINERS, HOSES, AND FITTINGS,
REPLACE
INITIAL SETUP:
Personnel Required:
Tools and Special Tools:
Two Watercraft Engineers, 88L
Tool Kit, Mechanic's Rail and Marine
(Item 1, Table 1, WP 0230 00)
References:
Equipment Condition:
FM 55-502
Diesel generator secured, locked out, and
TM 55-1905-242-24P (WP 0069)
tagged out IAW FM 55-502
Fire pump seacock CLOSED, locked out, and
tagged out IAW FM 55-502
REMOVAL--STRAINER
NOTE
Cotter pins, lockwashers, locking nuts, and similar locking devices shall be discarded after removal and replaced with
new cotter pins, lockwashers, locking nuts and similar locking devices.
1.
Remove the bolts (1), flat washers (2), lockwashers (3), and nuts (4) that secure the strainer (5) to the seacock (6) and to
the piping (7).
2.
Remove the strainer (5) and gaskets (8).
3.
If the strainer will be removed for an extended period of time, install an appropriate blanking plate over the seacock flange
to prevent inadvertent flooding of the vessel.
0144 00-1


 