TM 55-1905-242-14
DIRECT SUPPORT MAINTENANCE
FOR LANDING CRAFT, MECHANIZED (LCM-8) (ALL VESSELS WITH MOD 2 APPLICATION)
HULL, BITS, CHOCKS, TIE DOWNS, REPLACE/REPAIR
INITIAL SETUP:
Tools and Special Tools:
Personnel Required:
Tool Kit, Mechanic's Rail and Marine
(Item 1, Table 1, WP 0230 00)
One Certified Welder
Welding Shop, Trailer Mounted (Item 7,
(Trained in Confined Space Entry)
Table 1, WP 0230 00)
One Entry Supervisor/Attendant
Fire Watch as Required IAW FM 55-502
Equipment Condition:
References:
Vessel certified safe for HOT WORK IAW
FM 55-502
FM 55-502
Voids (if entry is required) prepared for con-
TB 43-0144
fined space entry with Confined Space En-
TB 55-1900-204-24
try Permit secured, IAW Organizational Con-
Organizational Confined Space Entry SOP
fined Space Entry SOP and FM 55-502
TM 55-1905-242-24P (WP 0002)
REPAIR
Repair of the hull, bitts, chocks, and tiedowns is by replacement of the failed or damaged component.
REMOVAL
WARNING
Only properly trained personnel may enter confined spaces, or act as entry supervisors
and/or attendants for those working in confined spaces. Before entering into a confined
space, the space must be cleared for entry and a Confined Space Entry Permit must be
secured. All entry into confined spaces must be in accordance with the Organizational
Confined Space Entry Standard Operating Procedure and FM 55-502. Entry into an
uninspected confined space can result in serious injury or death.
Grinding, needling, and chipping operations produce high velocity flying debris which
can become lodged in the skin or in the eyes. Grinding, needling, and chipping in
confined spaces can result in debris flying from unexpected directions. All personnel
working in the area must wear protective eyewear, gloves, and long sleeves when per-
forming grinding, needling and chipping operations. Failure to comply can result in
serious injury or death.
Unprotected exposure to arc welding rays can cause serious eye damage and radiation
burns to the skin. Never perform arc welding operations without using appropriate eye
and skin protection. Failure to comply can result in serious injury or death.
1.
If a confined space must be entered in order to perform work or to post a fire watch, prepare the space for confined space
entry and secure a Confined Space Entry Permit in accordance with the Organizational Confined Space Entry SOP and
FM 55-502.
0160 00-1
|
||