TM 55-1905-242-14
DIRECT SUPPORT MAINTENANCE
FOR LANDING CRAFT, MECHANIZED (LCM-8) (ALL VESSELS WITH MOD 2 APPLICATION)
HYDRAULIC STARTING SYSTEM RESERVOIR AND FILTERS, REPLACE
INITIAL SETUP:
Tools and Special Tools:
Materials/Parts:
Tool Kit, Mechanic's Rail and Marine (Item 1,
Hydraulic Fluid (Item 1, Table 2, WP 0230 00)
Table 1, WP 0230 00)
Cleaning Solvent MIL-PRF-680 (Item 2, Table 2,
Suitable Drain Pan
Gloves, Chemical Protective (Item 3, Table 2, WP 0230 00)
Equipment Condition:
Goggles, Industrial, No Vents (Item 4, Table 2,
Propulsion engines secured, locked out, and
tagged out IAW FM 55-502
Rag, Wiping (Item 5, Table 2, WP 0230 00)
All accumulators blown down
Sealant (Tape, Antiseizing) (Item 14, Table 2, WP 0230 00)
Packing, Preformed (p/n GA100201, qty 2)
Personnel Required:
Filter Element (p/n 6R020-060, qty 2)
Two Watercraft Engineers, 88L
References:
FM 55-502
TM 55-1905-242-24P (WP 0016)
REMOVAL
WARNING
Cleaning solvent is flammable and its vapor is potentially explosive. Do not use clean-
ing solvent in the vicinity of spark, open flame, or excessive heat. Do not use cleaning
solvent in unventilated spaces. Failure to comply can result in serious injury or death.
Do not allow hydraulic fluid or cleaning solvent to come in contact with unprotected
skin or eyes. Prolonged skin contact can cause illness or injury. Eye contact can cause
serious injury. Always wear chemical protective gloves and goggles when handling
used hydraulic fluid and cleaning solvent. Failure to comply can result in illness, seri-
ous injury, or death.
1.
Don protective gloves and goggles and position a suitable drain pan beneath the work area.
2.
Remove the nuts (1) and U-bolt (2) that secure the filter housing (3) to its bracket.
3.
Disconnect the hose (4) from the male connector (7) on the inlet side of the filter housing (3).
4.
Unscrew the filter housing (3) from the reducing hex nipple (5) connecting the filter housing and the control valve (6).
5.
Remove the male connector (7) from the inlet port of the filter housing (3).