16. Set the multimeter to the Vac (Volts alternating current) setting and check for voltage at all of the terminals on the terminal
block (31). If no voltage is noted, proceed to the next step. If voltage is noted, ensure that the shore power is properly
secured.
17. Label and disconnect the control box wiring (32) from the terminal block (31).
18. Unscrew the strain relief nuts (33) and pull the wiring (32) from the control box (30).
19. Remove the screws (34) that secure the forward inboard sound insulating panel (35) to the sound insulation frame (36).
Remove the forward inboard sound insulating panel.
20. Disconnect the quick disconnect plug (37) that connects the control wiring (38) to the main generator harness.
21. Remove the remaining screws (39) that secure the remaining panels (40) and sound insulation frame (36). Disassemble
and remove the panels and frame sections.
22. Loosen the hose clamps (41) that secure the raw water inlet hose (42) to the raw water pump inlet (43). Remove the raw
water inlet hose from the raw water pump inlet.
23. Remove the screws (44) that secure the fire pump clutch junction box cover (45), and remove the cover.
24. Set the multimeter to the Vdc (Volts direct current) setting. Connect one multimeter lead to each of the wiring connec-
tions and check for voltage. If no voltage is noted, proceed to the next step. If voltage is noted, ensure that the circuit
breaker is properly secured.
25. Label and disconnect the fire pump clutch wiring (46) and remove it from the junction box (47).
26. Remove the fire pump drive shaft (refer to WP 0145 00).
27. Label and disconnect the fuel inlet (48) and return (49) lines from the inlet (50) and discharge (51) fittings. Cap the fittings
and lines to prevent contamination from entering the fuel system.
28. Remove the mounting bolts (52), washers (53), and nuts (54) that secure the diesel generator base to the hull structure.
29. Carefully inspect the work area for any other interference that might foul the diesel generator as it is removed from the
engine room. Remove or relocate the interference as necessary.
30. Attach the lifting device to the diesel generator.
31. Carefully lift the diesel generator off its bed out of the engine room. Take care that the diesel generator does not foul on
the starboard propulsion engine or on any other equipment on the way out of the engine room.
0166 00-5
|
||