Custom Search
 
  
 
TM 55-1905-242-14
0186 00
REMOVAL (continued)
6.
Remove the bolts (8), lockwashers (9), and nuts (10) that secure the valve (7) to the overhead. Remove the valve.
INSTALLATION
1.
Position the valve (7) on the overhead and secure it with the bolts (8), lockwashers (9), and nuts (10).
2.
Connect the hoses (5) and return line (6) to the valve (7) using the labels from step 5 of Removal as a guide.
3.
Connect the control rod (3) to the shaft (4) with the clevis pin (2). Secure the clevis pin with the cotter pin (1).
4.
Remove the lockouts and tagouts and check the operation of the system, ensuring that the ramp operates properly and that
no leaks are present.
5.
Check the hydraulic fluid level in the reservoir and replenish as required.
6.
Dispose of used hydraulic fluid and contaminated materials in accordance with local regulations.
END OF WORK PACKAGE