Tweet |
Custom Search
|
|
|
||
TM 55-1905-242-14
DIRECT SUPPORT MAINTENANCE
FOR LANDING CRAFT, MECHANIZED (LCM-8) (ALL VESSELS WITH MOD 2 APPLICATION)
RAMP HOIST CONTROL VALVE, REPLACE
INITIAL SETUP:
Tools and Special Tools:
Materials/Parts:
Tool Kit, Mechanic's Rail and Marine (Item 1,
Hydraulic Fluid (Item 1, Table 2, WP 0230 00)
Table 1, WP 0230 00)
Gloves, Chemical Protective (Item 3, Table 2, WP 0230 00)
Suitable Drain Pan
Goggles, Industrial, No Vents (Item 4, Table 2,
Equipment Condition:
References:
Propulsion engines secured, locked out, and
tagged out IAW FM 55-502
FM 55-502
TM 55-1905-242-24P (WP 0090)
Personnel Required:
Two Watercraft Engineers, 88L
REMOVAL
WARNING
Do not allow hydraulic fluid or cleaning solvent to come in contact with unprotected
skin or eyes. Prolonged skin contact can cause illness or injury. Eye contact can cause
serious injury. Always wear chemical protective gloves and goggles when handling
used hydraulic fluid and cleaning solvent. Failure to comply can result in illness, seri-
ous injury, or death.
Hydraulic hoses and lines may be under pressure. Relieve pressure by operating the
appropriate control valve if possible. Loosen fittings on hose lines slowly. Allow oil to
run around threads of fitting, releasing pressure before disconnecting fitting. Releasing
pressurized oil suddenly can cause serious injury or death.
1.
Don chemical protective gloves and goggles.
2.
Position a suitable drain pan beneath the work area.
NOTE
Cotter pins, lockwashers, locking nuts, and similar locking devices shall be discarded after removal and replaced with
new cotter pins, lockwashers, locking nuts and similar locking devices.
3.
Remove the cotter pin (1) and clevis pin (2) that secure the control rod (3) to the shaft (4).
4.
Loosen, but do not remove, the hoses (5) and return line (6) to permit any residual hydraulic pressure or fluid to drain
from the system.
5.
Label and disconnect the hoses (5) and return line (6) from the valve (7).