Tweet |
Custom Search
|
|
|
||
TM 55-1905-242-14
GENERAL SUPPORT MAINTENANCE
FOR LANDING CRAFT, MECHANIZED (LCM-8) (ALL VESSELS WITH MOD 2 APPLICATION)
HYDRAULIC STARTING SYSTEM HAND PUMP, REPAIR
INITIAL SETUP:
Tools and Special Tools:
Materials/Parts (continued):
Tool Kit, Mechanic's Rail and Marine (Item 1,
Sealant (Tape, Antiseizing) (Item 14, Table 2, WP 0230 00)
Table 1, WP 0230 00)
Crocus Cloth (Item 22, Table 2, WP 0230 00)
O-Ring (p/n GA100113, qty 1)
Equipment Condition:
O-Ring (p/n GA100213, qty 1)
Hand pump removed (WP 0090 00)
Packing, Preformed (p/n RG100214, qty 1)
O-Ring (p/n GA100215, qty 1)
Personnel Required:
O-Ring (p/n GA100111, qty 1)
One Watercraft Engineer, 88L
Packing Plunger (p/n GA100097, qty 1)
Packing, Preformed (p/n RG100207, qty 1)
Materials/Parts:
Packing, Preformed (p/n RG100208, qty 1)
Hydraulic Fluid (Item 1, Table 2, WP 0230 00)
O-Ring (p/n GA100108, qty 1)
Cleaning Solvent MIL-PRF-680 (Item 2, Table
O-Ring (p/n GA100110, qty 1)
2,
Packing, Preformed (p/n RG100209, qty 1)
References:
Gloves, Chemical Protective (Item 3, Table 2,
Goggles, Industrial, No Vents (Item 4, Table 2,
TM 55-1905-242-24P (WP 0019)
Rag, Wiping (Item 5, Table 2, WP 0230 00)
DISASSEMBLY
WARNING
Cleaning solvent is flammable and its vapor is potentially explosive. Do not use clean-
ing solvent in the vicinity of spark, open flame, or excessive heat. Do not use cleaning
solvent in unventilated spaces. Failure to comply can result in serious injury or death.
Do not allow hydraulic fluid or cleaning solvent to come in contact with unprotected
skin or eyes. Prolonged skin contact can cause illness or injury. Eye contact can cause
serious injury. Always wear chemical protective gloves and goggles when handling
used hydraulic fluid and cleaning solvent. Failure to comply can result in illness, seri-
ous injury, or death.
1.
Don chemical protective gloves and goggles.
2.
Pull the pump handle grip (1) from the hand pump operating handle (2) only if the pump handle grip is damaged.
3.
Remove the hand pump operating handle (2) from the hand pump operating lever (3).