5.
Reheater controller (1-25-2) (figure 2, item 5). This controller turns the (1-25-2) reheater ON and OFF.
6.
Preheater controller (1-23-4) (figure 2, item 6). This controller turns the (1-23-4) preheater ON and OFF.
7.
Crew's mess fan coil unit (R1-25-2) controller (figure 2, item 7). This controller provides control of fan coil unit (5).
8.
Galley supply fan (S1-22-4) motor controller (figure 2, item 8). This motor controller provides control of galley supply
fan.
9.
Filter supply system (figure 2, item 9) (overhead). The filter supply system provides removal of dirt and foreign
particles from the outside air going to the galley supply fan.
10. AMS 2 supply fan (S1-22-2) motor controller (figure 2, item 10). This motor controller provides control for the
AMS 2 supply fan.
11. Fan coil unit (R 1-25-2) (overhead) (figure 2, item 11). The fan coil unit provides a circulating fan for main deck spaces
and an air conditioning coil for cooling.
12. Galley supply fan (figure 2, item 12). The vaneaxial fan provides makeup air for the galley ventilator hood.
13. Galley reheater (1-23-4) (figure 2, item 13). The (1-23-4) reheater reheats interior air recirculating to the fan coil unit.
14. AMS 2 supply fan (S1-22-2) (figure 2, item 14). The AMS 2 vaneaxial supply fan provides forced air supply to
AMS 2.
15. Steering gear oil reservoir (figure 2, item 15) (overhead). The steering gear reservoir has a 15.75 gal (59.6 liter)
capacity with a sight glass. This reservoir supplies hydraulic fluid for the steering gear system.
16. Refrigeration valves manifold (figure 2, item 16). The refrigeration valves manifold is a control center for the vessels