Tweet |
Custom Search
|
|
|
||
TM 55-1925-273-10-1
0094 00
2.
At the emergency switchboard, complete the following:
a.
Ensure that the MAIN SWBD BUS TIE CKT. BKR. CLOSED indicator (figure 3, item 1) is ILLUMINATED.
b.
Turn the ENGINE CONTROL SW. MAN. OFF AUTO. switch (figure 3, item 2) to the MAN. position.
c.
Push the MAIN SWBD BUS TIE CKT. BKR. CLOSED pushbutton (figure 3, item 3) to ON.
60
100
300 400
62
58
200
150
50
64
500
56
100
65
200
800
50
0
0
AC
AC
HERTZ
VOLTS
AMPERES
ENG GENERATOR
POWER AVAILABLE
VOLT METER
AM METER
OFF
OFF
LO
HI
4
1
3
MAIN SWBD BUS
MAIN SWBD BUS
TIE CKT.BKR.OPEN
TIE CKT.BKR.CLOSED
A PHASE
B PHASE
C PHASE
5
2
Figure 3. Emergency Switchboard
0094 00-4
|
||