TM 55-1925-273-10-1
0010 00
6.
Fire and emergency stop panel (figure 10, item 6). FM-200 manual pull box (above), HVAC SYS EMER STOP, the FO
XFER Pump EMER STOP (below), fire alarm pull station. The FM-20 manual pull box activates the engine room FM-
200 system. The EMER STOP boxes shut OFF fuel oil transfer pumps 1 and 2. The HVAC SYS EMER STOP shuts
OFF the AMS 1 and 2 supply fans, the engine room exhaust, and supply fans. The fire alarm pull station activates the
fire alarm when pulled.
7.
AMS 2 watertight door pump and reservoir system (figure 10, item 8). This system is used to OPEN and CLOSE the
AMS 2 watertight door.
8.
Fire extinguisher (figure 10, item 9). Portable fire extinguisher used to extinguish small fires on the main deck.
9.
Fire axe (figure 10, item 10). Used to aid crew in gaining immediate access to a locked or enclosed area in the case of
fire.
10. Fire alarm pull station (figure 10, item 11). Pulling the handle of the fire alarm pull station activates the fire alarm
system.
11. FM-200 manual pull box (figure 10, item 12). The FM-200 manual box provides a connection to the FM-200 fire
activation system in the engine room.
12. Tow machinery control panel (figure 10, item 7). The tow machinery control panel houses the logic control and cir-
cuitry connections for the tow machines.
END OF WORK PACKAGE
0010 00-16
|
||