TM 55-1925-273-10-1
0097 00
8.
At 440V power panel No. 1, set to OFF the following circuit breakers:
a.
FRESH WATER PUMP No.1 (REDUCTION GEAR). (figure 5, item 1)
b.
MAIN ENGINE LUBE OIL PRIMING PUMP No.1. (figure 5, item 2)
c.
MAIN ENGINE JACKET WATER HEATER No. 1./TURBO OIL PUMP No. 1./WATER LAY OVER PUMP
No. 1. (figure 5, item 3)
1
4
3
2
5
6
Figure 5. 440V Power Panel No. 1
PORT MAIN ENGINE SHUTDOWN
1.
At the EOS console, verify that the CONTROL AIR TRANSFER switch (figure 1, item 1) is in the EOS position.
2.
At the EOS condole, place the PORT MN ENG THROTTLE/CLUTCH lever (figure 1, item 3) in the NEUTRAL
(straight UP) position.
3.
Verify that the governor maintains the engine at idle speed. If idle speed cannot be maintained, notify the maintenance
supervisor.
0097 00-5