Custom Search
 
  
 
TM 55-1925-273-10-1
0011 00
ENCLOSED OPERATING STATION
5
4
3
6
2
1
23
2
22
21
7
20
19
18
17
16
15
2
8
10
2
13
14
9
11
12
Figure 2. Enclosed Operating Station (EOS)
1.
Sound powered telephone (figure 2, item 1). The sound powered telephone provides intraship communications.
2.
Window (figure 2, item 2). The window allows observation of the engine room.
3.
Vertical ladder (figure 2, item 3). This ladder provides an emergency exit from the EOS to the main deck.
4.
Scuttle (escape hatch) (figure 2, item 4). The scuttle provides an emergency exit from the enclosed operating station.
5.
Table/book rack (figure 2, item 5). The table/book rack is used for record keeping and storage.
6.
Master tank level indicator receiver panel, 7-channel (figure 2, item 6). The master tank level indicator receiver panel
has seven meters for remote monitoring of tank levels for the sewage holding tank, oily waste holding tank, potable
water tanks, and ballast water tanks.
7.
Fire and smoke detection panel, fire alarm bell, and key cabinet (figure 2, item 7). The fire and smoke detection panel
provides controls and indicators necessary for controlling and monitoring the fire detection system.
8.
Main switchboard (figure 2, item 8). The main switchboard includes facilities for the control of the SSDGs, including
paralleling and power distribution (440 Vac).
0011 00-4


 


Privacy Statement - Copyright Information. - Contact Us