Custom Search
 
  
 
TM 55-1925-273-10-1
0073 00
c.
In the engine room, on the port bulkhead, at the lube oil transfer pump motor controller, perform the following
actions:
(1)
Set the ON-OFF switch (figure 5, item 1) to the ON position
(2)
Verify that the POWER AVAILABLE indicator (figure 5, item 2) energizes.
(3)
Press the START pushbutton (figure 5, item 3).
(4)
Verify that the MOTOR RUN indicator (figure 5, item 4) energizes.
3.
Monitor the lube oil tank remote TLI (figure 8, item 1), and observe that the tank level decreases.
4.
When the lube oil tank is near empty, stop the lube oil transfer pump at the motor controller, by performing the following
actions:
a.
Press the STOP pushbutton (figure 5, item 5).
b.
Verify that the MOTOR RUN indicator (figure 5, item 4) goes out.
c.
Set the ON-OFF switch (figure 5, item 1) to OFF
d.
Verify that the POWER AVAILABLE indicator (figure 5, item 2) goes out.
5.
Secure the piping system by closing the following valves:
a.
Lo-15, LUBO STOR. TK. OUT. (figure 2, item 1)
b.
Lo-7, C.O.V. - LUBO XFER PMP. SUCT. (figure 2, item 2)
c.
Lo-14, LUBO XFER. TO OILY WST. STOR. TK. (figure 1, item 18)
6.
Line up Lo-18, LUBO SPLY. to the lube oil manifold position (figure 2, item 3)
7.
At the 440V power panel No. 1, set the LUBE OIL TRANSFER PUMP circuit breaker (figure 4, item 1) to OFF.
END OF WORK PACKAGE
0073 00-14


 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business