Custom Search
 
  
 
TM 55-1925-273-10-1
0073 00
4.
Fill the lube oil tank by directing the external source to begin pumping lube oil.
5.
On the TLI receiver module (figure 8, item 1), observe the fluid level meter. When the tank is near full, direct the
supplier to stop pumping.
6.
Allow all hoses to drain before disconnecting.
7.
Disconnect the supply hose, and recap the hose fill connection fitting.
8.
CLOSE and cap Lo-20, LUBO MN. DK. FILL CONN.
1
Figure 8. Lube Oil Tank Level Indicator
PUMPING THE CONTENTS OF THE LUBE OIL TANK TO THE OILY WATER STORAGE TANK
1.
Align the piping system.
a.
OPEN Lo-15, LUBO STOR. TK. OUT. (figure 2, item 1), located in the engine room, on the port side, below deck
level.
b.
OPEN Lo-7, C.O.V. - LUBO XFER PMP. SUCT. (figure 2, item 2), located in the engine room, on the port side,
below deck level.
c.
Line up Lo-18, LUBO SPLY. (figure 2, item 3), to send lube oil to the oily waste storage tank.
d.
OPEN Lo-14, LUBO XFER. TO OILY WST. STOR. TK. (figure 1, item 18), located on the starboard engine room
bulkhead, aft of SSDG 1.
2.
Align the electrical system, and start the lube oil transfer pump.
a.
Verify that the remote TLI (figure 8, item 1), is operational.
b.
At the 440V power panel No. 1, set the LUBE OIL TRANSFER PUMP circuit breaker (figure 4, item 1) to ON.