Tweet |
Custom Search
|
|
|
||
TM 55-1925-273-10-1
0074 00
! CAUTION
Do not refuel at a fill rate greater than 250 gal/min.
Prior to commencing a refueling operation, ensure that drip pans are in place at each connection,
and ensure that the scuppers are plugged to prevent accidental fuel spillage overboard.
1.
Align the fuel oil fill piping to receive fuel from an off hull source.
a.
If fueling from the port side OPEN FO-4, DK. FILL CONN (figure 8, item 2).
b.
If fueling from the starboard side OPEN FO-3, DK. FILL CONN (figure 8, item 1).
c.
CLOSE FO-8, C.O.V.-F.O. XFER PMP No. 1 DISCHARGE (figure 8, item 5).
d.
CLOSE FO-9, C.O.V.-F.O. XFER PMP No. 2 DISCHARGE (figure 8, item 7).
2.
Align the tank to be fueled:
a.
To fill a day tank directly from the shore connection proceed as follows:
(1)
CLOSE all of the valves on the fill side of the fuel oil manifold (figure 8, item 16).
(2)
OPEN FO-5, F.O. DAY TK EMERG FILL (figure 8, item 3).
(3)
To fill the emergency generator day tank, place the following valves in the OPEN position:
(a) FO-11, F.O. TO E.D.G. DAY TK (figure 8, item 11)
(b) FO-12, E.D.G. DAY TK FILL (figure 8, item 12), located in the emergency diesel generator room
(4)
To fill the starboard fuel oil day tank, OPEN FO-1, F.O. DAY TK. FILL (figure 8, item 13).
(5)
To fill the port fuel oil day tank, OPEN FO-2, F.O. DAY TK. FILL (figure 8, item 14).
b.
To fill the fuel oil storage tanks from the shore connection:
(1)
CLOSE FO-5, F.O. DAY TK EMERG FILL (figure 8, item 3).
(2)
At the fuel oil manifold, OPEN the manifold fuel oil fill valve(s) (figure 1 item 16) for the tank(s) selected to
be filled.
3.
Select the fuel supply line:
NOTE
The maximum fueling rate is 250 gal/min. The port and starboard fill connections join before
reaching the fuel oil header. If both external fuel oil connections are used to fuel the ship, ensure
that the total fueling rate does not exceed 250 gal/min.
a.
If the fuel supply line is connected to the port fuel oil deck connection, OPEN FO-18, F.O. FILL CONN PORT
(figure 12, item 1).
b.
If fuel supply line is connected to the starboard fuel oil deck connection, OPEN FO-39, F.O. FILL CONN. STBD
(figure 12, item 2).
0074 00-13
|
||