SETTING ALARMS
NOTE
The LMI allows the operator to specify minimum and maximum operating limits for various
crane functions. If any maximum preset limit is exceeded or the minimum limits are broken, the
LMI will alarm.
SET MAXIMUM LOAD ALARM
1.
Perform the Load Moment Indicator (LMI) Operation procedure in this work package.
2.
From the primary operating display screen, (figure 10) press the MODE button (figure 2, item 3) and down arrow button
(figure 2, item 4) on the LMI receiver panel (figure 2, item 2) to display the change min/max presets & select sensor
display screen (figure 19). LOAD is highlighted by default in this screen.
3.
Press the MODE button (figure 2, item 3) and down arrow button (figure 2, item 4) on the LMI receiver panel (figure 2,
item 2) to select the load preset selection screen (figure 20).
4.
SET MAX appears as the default setting in the load preset selection screen (figure 20). Press the MODE button (figure
2, item 3) and down arrow button (figure 2, item 4) on the LMI receiver panel (figure 2, item 2) to select the load main
max display screen (figure 21).
5.
Press the down arrow button (figure 2, item 4) or up arrow button (figure 2, item 5) on the LMI receiver panel (figure 2,
item 2) until the readout (figure 21, item 1) displays the maximum load value desired.
NOTE
Once saved, the settings will remain in effect even after the unit is powered off. If the settings are
not saved, they will not remain in effect the next time the unit is powered up.
6.
Save the setting by pressing the MODE button (figure 2, item 3) and down arrow button (figure 2, item 4) on the LMI
receiver panel (figure 2, item 2) once. The saving screen (figure 9) will appear briefly. When the save is complete, the
saving screen will be replaced by the load preset selection screen (figure 20).
7.
Press and hold the MODE button (figure 2, item 3) and push the up arrow button (figure 2, item 5) on the LMI receiver
panel (figure 2, item 2) twice to return to the primary operating display screen (figure 10).