0086 00
Change MIN/MAX Presets & Select Sensor:
<LOAD> ANGLE
RADIUS TIP WIND
Figure 19. Change Min/Max Presets & Select Sensor Screen
<SET MAX>
TARE
DERATE
Figure 20. Load Preset SelectionScreen
1
Set
LOAD MAIN
MAX: 000 LB
Accept by Mode , Change by
buttons.
Figure 21. Load Main Max Display Screen
SET MAXIMUM BOOM ANGLE ALARM
1.
Perform the Load Moment Indicator (LMI) Operation procedure in this work package.
2.
From the primary operating display screen, (figure 10) press the MODE button (figure 2, item 3) and the down arrow
button (figure 2, item 4) on the LMI receiver panel (figure 2, item 2) to display the change min/max presets & select
sensor display screen (figure 19).
3.
Press the down arrow button (figure 2, item 4) on the LMI receiver panel (figure 2, item 2) and scroll through the
selections until ANGLE is highlighted.
4.
Press the MODE button (figure 2, item 3) and down arrow button (figure 2, item 4) on the LMI receiver panel (figure 2,
item 2) once to reach the angle alarm menu screen (figure 22). If SET MAX is not already highlighted, press the up
arrow button (figure 2, item 5) or the down arrow button (figure 2, item 4) on the LMI receiver panel (figure 2, item 2)
until SET MAX is highlighted.
5.
Press the MODE button (figure 2, item 3) and the down arrow button (figure 2, item 4) on the LMI receiver panel (figure
2, item 2) to reach the maximum angle alarm setting screen (figure 23).
6.
Press the down arrow button (figure 2, item 4) or the up arrow button (figure 2, item 5) on the LMI receiver panel (figure
2, item 2) until the readout (figure 23, item 1) displays the angle value desired.
NOTE
Once saved, the settings will remain in effect even after the unit is powered off. If the settings are
not saved, they will not remain in effect the next time the unit is powered up.
7.
Save the setting by pressing the MODE button (figure 2, item 3) and the down arrow button (figure 2, item 4) on the
LMI receiver panel (figure 2, item 2) once. The saving screen (figure 9) will appear briefly. Once the save is complete,
the saving screen will be replaced by the angle alarm menu screen (figure 22).
0086 00-9