8.  Press and hold the MODE button (figure 2, item 3) and push the up arrow button (figure 2, item 5) on the LMI receiver
panel (figure 2, item 2) twice to return to the primary operating display screen (figure 10).
SET MIN
SELECT SENSOR
<SET MAX>
Figure 22. Angle Alarm Menu Screen
1
Set
ANGLE MAIN
MIN:  78.0 deg
Accept by Mode , Change by
buttons.
Figure 23. Maximum Angle Alarm Setting Screen
SET MINIMUM BOOM ANGLE ALARM
1.
Perform the Load Moment Indicator (LMI) Operation procedure in this work package.
2.
From the primary operating display screen, (figure 10) press the MODE button (figure 2, item 3) and the down arrow
button (figure 2, item 4) on the LMI receiver panel (figure 2, item 2) to display the change min/max presets & select
sensor display screen (figure 19).
3.
Press the down arrow button (figure 2, item 4) on the LMI receiver panel (figure 2, item 2) and scroll through the
selections until ANGLE is highlighted.
4.
Press the MODE button (figure 2, item 3) and the down arrow button (figure 2, item 4) on the LMI receiver panel (figure
2, item 2) once to reach the angle alarm menu screen (figure 22). If SET MIN is not already highlighted, press the up
arrow button (figure 2, item 5) or the down arrow button on the LMI receiver panel until SET MIN is highlighted.
5.
Press the MODE button (figure 2, item 3) and the down arrow button (figure 2, item 4) on the LMI receiver panel (figure
2, item 2) to reach the minimum angle alarm setting screen (figure 24).
6.
Press the down arrow button (figure 2, item 4) or the up arrow button (figure 2, item 5) on the LMI receiver panel (figure
2, item 2) until the readout (figure 24, item 1) displays the angle value desired.
NOTE
Once saved, the settings will remain in effect even after the unit is powered off. If the settings are
not saved, they will not remain in effect the next time the unit is powered up.
7.
Save the setting by pressing the MODE button (figure 2, item 3) and the down arrow button (figure 2, item 4) on the
LMI receiver panel (figure 2, item 2) once. The saving screen (figure 9) will appear briefly. Once the save is complete,
the saving screen will be replaced by the angle alarm menu screen (figure 22).
8.
Press and hold the MODE button (figure 2, item 3) and the up arrow button (figure 2, item 5) on the LMI receiver panel
(figure 2, item 2) twice to return to the primary operating display screen (figure 10).