TM 55-1925-273-10-1
0086 00
1
Set
ANGLE MAIN
MIN: 50.0 deg
Accept by Mode , Change by
buttons.
Figure 24. Minimum Angle Alarm Setting Screen
SET MAXIMUM RADIUS ALARM
1.
Perform the Load Moment Indicator (LMI) Operation procedure in this work package.
2.
From the primary operating display screen, (figure 10) press the MODE button (figure 2, item 3) and the down arrow
button (figure 2, item 4) on the LMI receiver panel (figure 2, item 2) to display the change min/max presets & select
sensor display screen (figure 19).
3.
Press the down arrow button (figure 2, item 4) on the LMI receiver panel (figure 2, item 2) and scroll through the
selections until RADIUS is highlighted.
4.
Press the MODE button (figure 2, item 3) and the down arrow button (figure 2, item 4) on the LMI receiver panel (figure
2, item 2) once to reach the radius alarm menu screen (figure 25). If SET MAX is not already highlighted, press the up
arrow button (figure 2, item 5) or the down arrow button on the LMI receiver panel until SET MAX is highlighted.
5.
Press the MODE button (figure 2, item 3) and the down arrow button (figure 2, item 4) on the LMI receiver panel (figure
2, item 2) to reach the maximum radius alarm setting screen (figure 26).
6.
Press the down arrow button (figure 2, item 4) or the up arrow button (figure 2, item 5) on the LMI receiver panel (figure
2, item 2) until the readout (figure 26, item 1) displays the radius value desired.
<SET MIN>
SET MAX
Figure 25. Radius Alarm Menu Screen
1
Set
MAIN Radius
MAX:
5 ft
Accept by Mode , Change by
buttons.
Figure 26. Maximum Radius Alarm Setting Screen
0086 00-11