Custom Search
 
  
 
TM 55-1925-273-10-1
0090 00
WARNING
Do not operate the pump unit in confined spaces unless the exhaust hose is connected to
carry the toxic engine exhaust gases to weather. Failure to comply can result in serious
injury or death.
5.
Check the engine lube oil for proper level prior to starting the pump:
! CAUTION
When checking the oil level, ensure that the pump unit is sitting level. If it is tilted, too much or
too little oil may be installed. Overfilling the recommended oil level may cause the engine to
consume too much oil and the oil temperature may become dangerously high. Operation of the
pump unit with the oil level below the recommended level may cause severe damage to the
engine. Never check the engine lube oil level with the engine running.
a.
Unscrew the oil dipstick (figure 1, item 1).
b.
Wipe the dipstick (figure 1, item 1) clean and then dip into the oil sump (figure 1, item 2).
3
4
1
2
Pump end and cage removed for clarity.
Figure 1. P-100 Portable Dewatering Pump
0090 00-2


 