Custom Search
 
  
 
TM 55-1925-273-10-1
0097 00
! CAUTION
If the turbocharger lube oil pump fails to operate when the engine is shut down and the low turbo
oil pressure alarm sounds, restart the engine immediately. Idle the engine 15 additional minutes
with no load to prevent turbocharger damage.
If engine restart is not possible within 2 minutes, do not restart the engine until the turbocharger
lube oil pump has been restored and the engine has been allowed to cool, or damage to the
turbocharger could result.
NOTE
The starboard main engine can also be stopped by pressing the starboard main engine STOP
pushbutton on the EOS control panel.
5.
At the starboard main engine control panel, STOP the starboard main engine by pressing the ENGINE STOP pushbutton
(figure 2, item 1).
TOTAL HOURS
ENGINE RPM
1
ENGINE
CONTROL
HEATER
START
POWER
ON
O
ENGINE
HEATER
ON
F
STOP
OFF
F
ANNUNCIATOR
ALARM
TEST
ON
ALARM
OFF
LUBEOIL
FUELOIL
STARTAIR
DATE
MODEL
SERIALNO.
TOTALHOURS
ENGINERPM
ANNUNCIATOR
Figure 2. Main Engine Control Panel
0097 00-2


 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business