TM 55-1925-273-10-2
0159 00
ITEM INTERVAL MAN-
ITEM TO BE
PROCEDURE
EQUIPMENT
NO.
HOUR
CHECKED OR
NOT READY/
SERVICED
AVAILABLE IF:
11
Before
1.0
PILOTHOUSE
Inspect console for cleanliness. Clean as
Any critical control
CONSOLE
required. Look for any loose, missing,
or indicator that is
or broken switches or controls, gauges,
unserviceable.
indicator lights, or obvious damage.
Ensure that throttle controls operate
smoothly and do not bind.
12
Before
0.2
Engine Order
Conduct test with the EOS to ensure
No communication
Telegraph
communication. Move selector through
with EOS.
each position ensuring corresponding
indicator lights.
13
Before
0.2
Remote Propulsion
Press and hold LAMP TEST button. All
Indicator Panel
lights should light. Adjust intensity of
the lights using the DIMMER control.
Bow Thruster
Clearview Screen
Control Panel
CONTROL AIR PRESSURE
STBD
GAUGE and COMMAND
Pilothouse
TRANSFER
Console
EOT
Ship Whistle
Pull Valve
Remote Propulsion
Indicator Panel
0159 00-5