Custom Search
 
  
 
TM 55-1925-273-10-2
0159 00
ITEM INTERVAL MAN-
ITEM TO BE
PROCEDURE
EQUIPMENT
NO.
HOUR
CHECKED OR
NOT READY/
SERVICED
AVAILABLE IF:
! CAUTION
14
Before
0.2
Fire Pump START/
STOP Panel
Ensure that the fire pumps are properly
aligned (WP 0071 00, volume 1) prior
to performing this check. Failure to comply
with this caution will result in damage to
the fire pumps.
Press each remote START/STOP switch
Switch will not
and ensure that each pump STARTs and
START or
STOPs properly.
STOP pumps.
FIRE PUMP
NO.
START/STOP
1
Panel
NO.
2
FIRE PUMP REMOTE CONTROL
NOTE:
VALVE ALIGNMENT OF STANDBY FIRE
PUMP FOR FIREMAIN SERVICE SHALL BE
MAINTAINED AT ALL TIMES.
SEARCHLIGHTS
WARNING
DO NOT energize this circuit before
first checking to ensure that the
protective lamp cover has been
removed. Use extreme care when
performing maintenance work or
operating the searchlight. Dangerously
high voltage (over 50,000 VOLTS) is
used in the lamp starting circuit.
15
Before
0.2
Test
Test operate searchlights.
0159 00-6


 