(b)
Pump - Flush with fresh water. Drain and blow dry, drain pot strainer on suction. Attach strainer cap with
new gasket/"0" ring adjacent to strainer ready for assembly, leaving strainer open to D/H.
NOTE
This item will be worked in conjunction with item 23.(a). Both should be
the last system to process.
12.
Air Conditioner and Systems:
(a)
Air Conditioner - No preservation required.
(b)
Raw Water Circulating Piping/Condenser - Back flush with fresh water, drain and blow dry.  Flush
overboard from condenser with fresh water, drain and blow dry. Lines may be disconnected as required to
effect flushing and draining, after which all will be reconnected, left in a ready status. All valves in this
system will be left in the closed position. The sea chest valve will be wired in the closed position. The
duplex strainer shall be drained, dried, and the caps reinstalled. A Red Tag will be placed on the valve as a
warning.
(c)
Pump, Raw Water Circulating - Flush with fresh water, drain and blow dry. Leave drain plugs holes openr
Bag and tag drain plugs and hang next to the opening, or on the pump.
CAUTION
In working this system, do not open any of the valves to the chlorination
plant.
13.
Chlorination Plant - Drain system piping, flush with fresh water and blow dry.
14.
Shop Equipment
(a)
Drill Press - Exposed metal surfaces, (spindle, chuck, post, etc. ) clean and coat with light film of P-10
grade 30.
(b)
Bench Vise - Clean and coat with light film of P-10 grade 30.
(c)
Hand Press - Clean and coat with light film of P-10 grade 30.
(d)
Bench Grinder - Clean, no preservation required.
15.
Hydraulic System - Located in #1 and #5 voids, respectively.
(a)
Hydraulic System for Crane - Ensure system reservoir is filled to operating level Fluid to be IAW Instruction
Manual Chapter 8.
(b)
Hydraulic System for Hose Reel - Ensure system reservoir is filled to operating level
16.
Equipment, Crew Quarter
(a)
Refrigerator- Secure power. Secure door by blocking in a slightly open position to allow air circulation No
further preservation required.
(b)
Drinking Fountain - Secure power. Drain no further preservation required.
(c)
Hot plate and coffee pot- clean, dry and secure in place.
E-6


 


Privacy Statement - Copyright Information. - Contact Us