Custom Search
 
  
 
TB 55-1900-231-15
17.
Fire Protection System
(a)
Smoke Detection System - No preservation required.
(b)
Fixed CO2 Systems - No preservation required.
(c)
Portable CO2 Extinguishers - Left in place, weighed and tagged, seals intact. No preservation required.
18.
Monitoring System - No preservation required. New 24VDC battery, in dry state, will be secured in tray. Coat
cable lugs and battery post with P-11 and leave unconnected.
19.
Control/Alarm and Shutdown System - No preservation required. New batteries, in a dry state, will be secured in
tray. Coat cable lugs and battery post with P-11 and leave unconnected.
20.
Salvage Pump (P-250) - Exercise pump for test. When completing exercise, with engine still running shut off gas
from tank, let engine continue to run all gas from the carburetor.
(a)
Engine - After cylinder heads have cooled to 1000 F or below, remove plugs, spray 1/2 oz. of P-10 grade 30
into each cylinder.
(b)
Pump - Flush pump with fresh water and blow dry. Bag and tag plugs and secure on the pump or the frame.
Apply P-11 to cap threads, suction and discharge.
21.
Spare R. O. Engines - Remove valve covers, fog running gear (rockers, push rods, springs, shafts, etc. ) with P-
10 grade 30. Reinstall valve covers. Clean exposed shafts (fuel control shaft, etc.) and coat with P-11.
22.
Spare R. O. Pumps - Clean exposed shafts, key, and key way and coat with P-11. In the final when the vessel is
placed under D/H remove the tape from the suction and discharge.
23.
TANKS
(a)
Ballast Tank - Dry and clean, offset access cover secured on a couple of studs to leave tank open to D/H.
Bag and tag the remaining securements and a new gasket adjacent to access ready for assembly. Cap/close
off tank vent
NOTE
The fill and drain piping to this tank will be processed in Item 3.
(b)
Product Water Storage Tanks Nos. 1, 2, 3, and 4 - Dry and clean, offset access covers secured on two
studs to leave tanks open to D/H. Bag and tag the remaining securements with a new gasket adjacent to the
respective tank access, ready for assembly. The vents for these tanks remain open as they vent inside the
R. O. Space D/H envelope. Storage tanks are preserved with an epoxy paint system.
NOTE
The fill piping for these tanks will be processed in Item 2. (c). The
discharge piping will be processed in Item 5.(b).
(c)
Drinking Water Storage Tank - Dry and clean, offset access cover on two studs to leave tank open to D/H.
Bag and tag the remaining securements with a new gasket adjacent to the access, ready for assembly. The
vent for this tank will be sealed. Storage tank is preserved with an epoxy paint system.