TM 5-2805-261-13
2.
The circuit is open (broken) if the needle
4-12.
WIRE TESTING WITH MULTIMETER.
doesn't move.
NOTE
3.
There is a loose connection in the circuit being
The ohms scale is used for continuity
tested if the needle jumps or flickers.
and short circuit testing.
C. Replace or repair the circuit if you see "2" or "3"
NOTE
above.
Set up and zero the multimeter before
each test and before testing each
4-14.
TESTING FOR SHORT CIRCUITS.
wire.
A. Connect one probe to one circuit and the other probe
CAUTION
to the other circuit, or ground.
Always disconnect the circuit being
tested. Failure to do this can damage
B. Watch needle movement.
1.
The circuits are short circuited if the needle
4-13.
TESTING FOR CONTINUITY.
swings to the far right over the 0 on the top
scale.
A. Connect meter probes to both terminals of the circuit
being tested.
2.
The circuits are intermittently short circuited if
the needle jumps or flickers.
B. Watch needle movement.
3.
The circuits are not short circuited if the
1.
The circuit has continuity if the needle swings
needle doesn't move.
to the far right, over the 0 on the top scale.
C. Replace or repair the circuit if you see "1" or "2",
above.
Section V. MANUAL STARTER MAINTENANCE
MAINTENANCE SUMMARY. This task covers:
Disassembly/assembly of the starter rewind
INITIAL SETUP
Personnel Required
General Safety Instructions
1
Safety glasses must be worn during this task because of tension in
rewind spring.
TASK SUMMARY
NO.
TASK
REFERENCE
REMARKS
1
Disassembly/assembly of
starter rewind
2
Cleaning and inspection
4-8


 