Table 3-37. Hydrostarter - Loss of Accumulator Precharge
(Nitrogen) - Troubleshooting.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. Loss of accumulator precharge (nitrogen).
Step 1.
Check for damaged seal ring on piston.
Some nitrogen precharge, but no fluid
pressure in the system, bubbles and
foaming in reservoir indicates that
nitrogen is leaking past the seal ring
on accumulator piston. Refer to
Direct Support Maintenance.
Step 2.
Check for defective air valve.
Release pressure in system by opening
relief valve on side of hand pump.
Loosen hex lock nut on nitrogen valve
approximately 3/4 turn to release
remaining precharge before attempting
to remove v alve from accumulator.
Replace the air valve. Refer to Direct
Support Maintenance.
Step 3.
Check for damaged seal ring between shell and end
cap.
Apply light oil on threaded end of accum-
ulator at end of the cap. Bubbling of the
oil indicates a leak past the end cap seal.
Refer to Direct Support Maintenance.