Tweet |
Custom Search
|
|
|
||
TM 55-1905-219-14-3
Table 3-60. Anchor Winch Engine - Hard Starting Troubleshooting.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1.
Engine will not rotate.
Step 1.
Check hydrostarter.
Refer to tables 3-67 thru 3-77, and perform the
operations listed.
Step 2.
Check for defective starting motor switch.
Replace the starting motor switch at the control
station. Refer to paragraph 3-138.
Step 3.
Check for internal seizure.
Hand crank the engine at least one complete
revolution. If the engine cannot be rotated a
complete revolution, internal damage is indicated
and the engine must be disassembled to ascertain
the extent of damage and the cause. Refer to
paragraph 3-140.
2.
Low cranking speed.
Step 1.
Inspect for improper lubricating oil viscosity.
LUBRICATING OIL GRADES
DESCRIPTION
SPECIFICATION
OES (Sub Zero)
MIL-L-10295
OE/HDO - 10
MIL-L-2104
OE/HDO - 20
MIL-L-2104
OE/HDO - 30
MIL-L-2104
NOTE
At low ambient temperatures, use of a starting aid will reduce the cranking time.
3-179
|
||