Custom Search
 
  
 
TM 55-1905-219-14-3
Table 3-60. Anchor Winch Engine - Hard Starting
Troubleshooting (Cont).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
2.
Low cranking speed (Cont).
Step 2.
Check for loose hydrostarter connections or faulty starter.
Tighten the starter connections. Refer to tables
3-72 thru 3-77 for hydrostarter problems.
3.
No fuel.
Step 1.
Check for air leaks, flow obstruction, faulty fuel
pump, and faulty installation.
To check for air leaks, flow obstruction, faulty
fuel pump or faulty installation, consult the No
Fuel or Insufficient Fuel table 3-62.
Step 2.
Check for injector racks not in full-fuel position.
Check for bind in the governor-to-injector linkage.
Readjust the governor and injector controls if
necessary. Refer to paragraph 3-142 and 3-161.
3-180


 