TM 55-1905-220-14-3
Table 3-41.
Hydrostarter - Cranking Cycle Too Short -
Troubleshooting (Cont).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1.
Cranking cycle is too short (Cont).
Step 4.
Check for accumulator precharge too low.
Open the bypass valve on the hand pump to discharge oil from the accumulator.
Install a gaging assembly on the accumulator air valve. If precharge is less than
1500 psi (2034 kPa) add nitrogen. Make sure pre- charge holds by testing for
nitrogen leakage. Refer to table 3-37.
3-124
|
||