TM 55-1905-221-14-2
5-12.1.
ALTERNATOR (Continued)
LOCATION/ITEM
ACTION
REMARKS
TESTING (Cont)
b.
Check resistance between each
rotor slip ring (1 and 2), and
rotor frame (3) with an ohmmeter.
Resistance should be very high
or indicate open circuit. If
resistance is low, winding is
shorted, and rotor assembly
must be replaced.
13.
Brush
a.
Check resistance between brush
Assembly
terminals (1 and 2), and brush
holder (3). Ohmmeter should
indicate open circuit or very
high resistance. If there is
no or low resistance, replace
brush assembly.
5-168


 