Tweet |
Custom Search
|
|
|
||
TM 55-1905-222-14
Operator Preventive Maintenance Checks and Services - (Continued)
Equipment is Not
PROCEDURES
INTERVAL
ITEM
Item To Be
Ready/Available If:
Check for and have repaired
NO.
Inspected
or adjusted as necessary
B
D
A
W
M
25
Voltage Regula-
Inspect regulator to ensure it is
tor
mounted securely Check that
electrical connections are clean
and tight
26
Voltage Protec-
Inspect protector to ensure it is
tor
mounted securely Check that
electrical connections are clean
and tight
27
Lighting Fix-
Inspect fixtures and switches
tures and
for proper operation of lights
Switches
Inspect fixtures for secure
mounting, cracked, broken or
missing guards, globes and
bulbs Inspect wiring connect-
ing switches and fixtures for
wear, fraying and proper rout-
ing Replace burned out bulbs,
fixtures and switches as neces-
Propulsion
Controls and
28
a Throttle
Inspect linkage from control
Linkage is bent, kinked,
Linkage
head to governor for cable
severed or loose so as to affect
damage Ensure linkage is free
proper control of the throttle
to move and is not bound at
any point AdJust (para 4-23)
and/replace defective compo-
nents of throttle linkage as nec-
essary (para. 5-8)
Inspect shifting and throttle
linkage ball joints
Change 6 2-27
|
||