6-18 REPAIR ACCUMULATOR (Continued).
d. Using a loading sleeve, covering the
spilt ring groove, insert piston (16) into
housing bore with the closed end first
Check seal rings to be sure they are
not twisted or otherwise damaged.
e. Push piston half way down in housing
bore.
f.
Install back-up seal rings (14) to oil end
cap (15) Coat seal rings with light
grease BM1546 to hold in place.
g. Slide end cap (15) with oil port Into
housing (7) beyond the normal position
Use loading sleeve.
NOTE
Be sure end cap is on side with head of the piston.
h. Install ring segments (13 and 12)
and hold in place.
i. Push piston (16) against oil end
cap (15) to position end cap
against retainer plate.
J. Install retainer plate (10) Then,
secure end cap (15) with
lockwashers (9), and screws (8).
k. Install back-up seal rings (14) to
end cap (11). Coat seal rings with
light grease BM1546 to hold in
place
I. Slide end cap (11) into housing (7)
beyond the normal position.
m. Install ring segments (13 and 12)
and hold in place.
n. Apply pneumatic or mechanical
force of 50 PSI (344.7 kPa)
maximum to position end cap
against retainer plate (10).