Tweet |
Custom Search
|
|
|
||
TM 55-1905-223-24-18-1
e.
Install discharge piping assembly at nipple (19) into outlet side of pump.
f.
Position pipe wrench on nipple for clockwise rotation to secure piping to
pump.
Position pump assembly and piping on baseplate (13).
g.
h.
Connect pump assembly (21) to motor (12) at coupling (11).
i.
Position shaft bracket (6) over mounting screw holes in baseplate.
Secure shaft bracket with four hexhead capscrews (16), lockwashers
j.
(15) and hex plain nuts (14).
k.
Position coupling guard (10) on baseplate with mounting screw aligned.
l.
Secure coupling guard with two hexhead capscrews (9), lockwashers (8) and
hex plain nuts (7).
m.
Secure motor (12) with four hexhead capscrews, lockwashers and hex plain
nuts.
n.
Install pump relief elbow (20) on pump. Position pipe wrench on elbow
for clockwise rotation to secure nipple (22) and valve (1) section pump.
o.
Connect pump relief piping at connector (2).
Connect suction piping at union (4) on inlet side of pump.
p.
Connect discharge piping at union (17) on outlet side of pump.
q.
r. Open pump relief valve (1).
s. Open pump suction (3) and discharge (18) valves.
Remove tags and connect electrical leads at junction box on motor (12).
t.
u.
Run to test.
|
||