Replace/Repair Linear Directional Control Valve.
a. Removal, b. Disassembly, c. Repair, d. Assembly,
This task covers:
e. Replacement.
INITIAL SETUP
Equipment Condition
Tools
A i r supply to linear directional
Tool kit, general mechanic's,
control valve secured and tagged
"Out of Service - Do Not Operate" at
LPA-8 (Supply to Control Air).
Materials/Parts
(TM 55-1905-223-10)
Preformed packing P/N H134-66
Preformed packing P/H H136-93
Gasket P/N M223-006
Preformed packing P/N H135-27
Warning tags, Item 1, Appendix C
Teflon tape, Item 5, Appendix C
WARNING
To avoid personal injury; slowly open tubing
connection to allow builtup pressure to
escape.
NOTE
Cap or plug tubing connections when removed
to ensure no contamination enters lines.
a.
Disconnect tubing at connections (3, 4, 5, 6, and 7).
b. Remove four machine bolts and self-locking nuts (2).
c.
Remove control valve (1) from bracket (8).
DISASSEMBLY (FIGURE 2-111)
Remove machine screw (1), stop stem (2), lockwasher (3), and stem (4).
a.
b.
Remove bearing assembly (5).
c. Remove valve body (6) from housing (14).