NOTE
When setting up dogs on watertight doors. A
dog on the opposite side from the hinges
s h o u l d be set up first with sufficient
pressure to hold the door. Two dogs should
then be set up snugly on the hinge side.
Then all the dogs should be set up evenly to
ensure a good bearing all around.
( 4 ) If the door is watertight, the gasket will show an unbroken chalk line.
(5) If the line is broken, adjust the dogs and retest.
CAUTION
Dogs should not be adjusted to give more
than 1/8" compression.  Excessive pressure
is harmful to the gasket.
f. Operate door and check for smooth and positive dogging action.
Install (if removed in step a of removal procedure) grounding straps (6,
g.
FIGURE 2-168) to hinge blades (2) and to bulkhead.


 