Tweet |
Custom Search
|
|
|
||
TM 55-1905-223-24-18-1
Repair Butterfly Valves.
a. Removal, b. Repair, c. Replacement.
This task covers:
Tools
At Ship Service Switchboard set
Tool kit, general mechanic's,
BILGE/BALLAST circuit breaker to the
OFF position. Set FIRE PUMP 1 and
FIRE PUMP 2 circuit breakers to the
Materials/Parts
OFF position. Tag switches "Out of
Service - Do Not Operate."
Piping system, bilge ballast and
firemain P/N 88529024, refer to
TM 55-1905-223-24P
Warning tags, Item 1, Appendix C
U t i l i t y p a i l , Item 13, Appendix C
Use extreme care when disconnecting. Escaping system
pressure of fluid could cause injury.
NOTE
All butterfly valves are replaced in the same manner.
Isolate valve from piping system.
a.
(1) Trace inlet piping (1, FIGURE 2-262) to nearest manually operated shutoff
valve.
( 2 ) Close shutoff valve.
(3) Trace outlet piping (4) to nearest manually operated shutoff valve.
( 4 ) Close shutoff valve.
2-989
|
||