Custom Search
 
  
 
TM 55-1905-223-24-18-1
Repair Lavatory Basin.
2-362.
a. Removal, b. Repair, c. Replacement.
This task covers:
INITIAL SETUP
Equipment Condition
Tools
Faucet removed (para.2-323)
Tool kit, general mechanic's,
General Safety Instructions
Materials/Parts
Clean up spills immediately with
Piping system, sewage and
.
d i s i n f e c t a n t .  Spills create an
plumbing P/N 8528023,
unsafe working area.
refer to TM 55-1905-223-24P
After contact with sewage
.
contaminated equipment, clean
yourself with disinfectant soap
before performing hand-to-mouth
functions such as eating, drinking,
smoking, etc.
Toxic and flammable vapors are
l
generated in the sewage system.
Provide ventilation from outside
source before removing covers, drain
plugs, hoses, valves, and fittings.
Avoid open flames and prolonged
breathing of fumes.
REMOVAL
Disconnect drain piping (4) from lavatory.
a.
Remove nuts (3) and lockwashers (2).
b.
c.
Remove lavatory (1) from bulkhead.
REPAIR
Repair at this level of maintenance is by replacement of the lavatory (1).