(5) Remove terminal lug (8) at rear of fuseholder.
(6) Remove fuseholder from front of cover plate.
(7) Remove cover plate.
(8) Tag and disconnect leads from stud terminals (60) on electrolytic fixed capacitor (61).
(9) Remove two plain hex nuts (51), lockwashers (50), and machine screws (49) securing shock
pad (62) to support mount.
(10) Remove shock pad and electrolytic fixed capacitor (61).
(11) Remove terminal marker strip (64) from terminal block (63).
(12) Tag and disconnect electrical leads from wire hook-up (52).
(13) Disconnect cable ties (53) from cable harness.
(14) Remove terminal lug (8) securing tie mounting device (54) to support mount.
(15) Remove tie mounting device.
(16) Remove two plain hex nuts (51), lockwashers (50), and machine screws (49) securing
terminal block (63) to support mount.
(17) Tag and disconnect electrical leads from power transformer (65) by removing four terminal
lugs (8).
(18) Remove four plain hex nuts (27), lockwashers (26), and machine screws (23) securing
power transformer (65) to support mount.
(19) Remove power transformer.
(20) Repeat steps (17) through (19) to remove power transformer.
(21) Remove identification markers (67) and (69).
(22) Tag and disconnect electrical leads from terminal block (70).
(23) Remove two plain hex nuts (51), lockwashers (50), and machine screws (49) securing
terminal block (70) to support mount. Remove terminal block.
(24) Pull electrical leads clear of nonmetallic grommet (68).
(25) Remove nonmetallic grommet.