FIGURE 3-92. Fresh Water Centrifugal Pump.
NOTE
To assist removal of centrifugal pump impeller retaining hex nut,
the pump shaft is held stationary by placing-either a screwdriver
or nail of suitable size through hole provided on the close
coupled pump shaft (Figure 3-93).
h. Install screwdriver or nail through hole in pump shaft (11, Figure 3-92).
i. Remove hex plain nut (9).
j. Remove impeller (10) by pulling straight off shaft.
3-385


 