Custom Search
 
  
 
TM 55-1905-223-24-3
Table 2-1. Preventive Maintenance Checks and Services
D-Daily
M-Monthly
Q-Quarterly
A-Annually
B-Biennially
E-Every 1600 Operating Hours
Item
Interval
Items To Be
No.
DM
Q
A
B
E
Inspected/Serviced
Procedures
10
Engine (General)-
Replace gaskets and damaged components as neces
CONT
continued
sary.
Visually inspect the front of the instrument panel for broken gauges, lenses or damage to
the panel face or cabinet.
WARNING
Turn off and tag all electrical power to the instrument panel and automatic
starting circuits. Failure to do may result in personal injury.
Open the instrument panel assembly by removing the two screws one each in top corners of
the panel. Swing the panel front down to expose the terminal board and the back of the
instruments and wiring connections.
Visually check all wiring and connections for loose or broken connectons. Secure or repair
i
wiring as necessary.
11
Generator (exterior)
WARNING
Before attempting any maintenance task on the generator set,
make sure the generator is removed from the line. Make sure
the engine is shut off and the automatic starting circuits on
engines are disabled to avoid injury to personnel.
2-12


 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business